A Room, Not a Façade: Generating Buildings You Can Walk Into
Last time we walked a robot from a painted sheet to a game-ready mesh. This week we pointed the same production line at something bigger and asked a harder question: can an image-to-3D model build a place? Not a façade to drive past — a building in Wasteland Arena you can steer a truck into and get out and walk around.
We expected the answer to be no. Generative 3D models are trained to produce a closed surface, and a closed surface is exactly the wrong thing here: you get a lovely garage with a door-shaped dark patch and solid rock behind it. That failure would have been invisible in every screenshot and fatal to the feature.
The line, unchanged from the robots
One prompt, one image, one mesh, then weld and reduce. The only new thing is the subject.

The middle pane is the whole trick and the third pane is why we trust it. A generated mesh can arrive inside-out or full of holes and look perfect in a normal render, because you are seeing the inside of the far wall where the near wall should be. Render it with backface culling on and those failures show up as wounds. Every mesh gets that pass, plus a census that counts holes and bad edges instead of eyeballing them.
One correction worth recording for anyone following along: our first prompt asked for a photograph, and got one — a beautiful straight-on elevation, cropped at both edges, useless. Image-to-3D wants an isolated scale model on a plain background with generous margin on every side. Ask for a product shot, not a photo.
It came back a room

That left-hand image is a camera 1.7 m off the floor, standing inside the building, looking back out through the door. There is a ceiling. There is a door header and two jambs. There is a workbench in the corner. It is not a shell.
The measurements agree, and we made them carefully, because “is it hollow” is easy to answer wrongly. Interior volume counts only empty space a flood fill can reach from outside the building — a sealed cavity inside a closed lump is not a room, however large. On this garage:
- 257.7 m³ of reachable interior, 54.4 m² of standable floor, and 0.02 m³ of sealed void
- a ground-level doorway 6.56 × 4.0 m with a 0.2 m sill — big enough for a truck to fit through, and, it turns out, not big enough for ours (see below)
- 11.53 × 10.30 × 6.0 m overall (height imposed; image-to-3D has no absolute scale, so we set one figure and the rest follow from the model’s proportions)
Big enough for a truck, too small for our truck
Here is the correction we did not see coming, and it is a good one. A 6.56 m opening comfortably passes a three-metre vehicle — in the real world. In this game the player is modelled as a circle with a 5.2 m radius, and the collision index anticipates body radii up to 5 m, so a doorway has to clear roughly 11 m before you can reliably drive through it without being shoved back out. The one enterable structure already in the game — the ruined hall — is built as five separate blockers around a 12 m gap, and that number is load-bearing rather than aesthetic: anything under one body diameter plus slack is a documented jitter trap.
Worse, collision here is the building’s whole bounding box. Two structures already ship with beautifully modelled doorways and you cannot walk into either of them, because the doorway is geometry and the collision is the box around it. So “generate a building with a door in it” was never going to be sufficient on its own, however good the door looked. The mesh was never the hard part.
That reframes the work rather than sinking it. It means an enterable building is a mesh plus a collision shell authored to match it — which we already knew we needed for a different reason, since a decimated mesh is not watertight enough to derive collision from anyway. And it means the doorway is a number we have to choose, not one we can hope a generator hands us.
The technique we expected to win, lost
Buildings are flat. Flat surfaces are what planar decimation exists for — it dissolves coplanar faces and should crush a wall to almost nothing. We were confident enough to make it the headline of the plan.

It lost at every single matched triangle count, by six to eight times, and it took forty-five minutes to lose where the alternative took seconds. The reason is the useful part: a generated wall is not flat, it is wavy. The model produces a surface that reads as a wall and undulates by millimetres, so a technique that exploits flatness has nothing to exploit. Quadric collapse doesn’t care and just gets on with it.
That is a fact about generated geometry rather than about architecture, which is a distinction with a consequence — see the last section.
There is a floor, and it is 39,524 triangles
Generated meshes arrive with their UV seams split, which reads as 438,475 boundary edges — almost none of them real holes. Weld them first (any reduction before welding tears every one into an actual hole) and you are left with 2,112. Excellent trade, with a bill attached: the weld converts those seams into 3,864 non-manifold edges, and Blender’s collapse will not simplify across them.
So we asked for 12,000 triangles and got 39,524, and no amount of asking moves it. Below that needs manifold repair or retopology and baked normal maps, which we have not built. The good news is that 40k is free: a 96 % reduction whose culled renders are indistinguishable from the million-triangle original, inside and out.
Where the instrument nearly lied, twice
Both worth writing down, because both would have shipped a wrong answer.
The opening that wasn’t a door. The largest opening in this building by area is 8.88 × 3.0 m — and its sill is 2.2 m off the ground. It is a gap under the roofline. Any measurement that reports “largest opening” hands you a door no vehicle can use, so we only count openings whose sill stands on the floor.
Believe the render, not the ruler. Measure hollowness on the decimated mesh and it reports the room shrinking from 257 to 74 m³ and the door narrowing to 2.78 m — while the render of that same mesh shows room, ceiling and daylight all intact. Collapse thins the 3–5 cm walls until the ray test stops registering them. That is the instrument failing, not the building. It does leave one real consequence: a decimated building is not watertight enough to derive collision from, so that gets authored separately.
All nine runs, and the garage was not a fluke

Every mesh was re-measured and re-rendered by a second agent that did not trust the first, and three of those graders overruled the report they were checking — on the civic hall, the roadhouse and the water tower the instrument disagreed with the render, and the render was right every time. Seven of nine came back hollow, four with a ground-level opening a truck-sized body would clear. Nothing scored above 7 out of 10: these are good raw meshes, not finished assets.
The camera angle was worth four grades
We ran the roadhouse twice. Same subject, same model, same settings. The only thing that changed was the picture we handed the generator.

From a straight-on elevation: a facade, no interior, a 0.60 m opening too narrow for a person. From a three-quarter view: a room you can reach, with an 8.58 × 3.14 m porch opening. Whether a generated building has an inside is decided by the conditioning view, not by the prompt and not by the model. An elevation gives it no parallax to infer depth from, so it returns what it was shown — one wall. Show it two and it builds a room. That is the most useful thing this whole run produced and it costs nothing to apply.
We tested the components idea, and it lost in an interesting way
The theory was good: generated buildings are wavy, so generate flat COMPONENTS instead — a brick wall panel, a floor tile, a roller door — where planar decimation finally has flatness to exploit, then assemble. We built eight of them and measured.
Half of it held, decisively. Simple parts really do decimate further, and we found the predictor: not simplicity but bad edges left after welding. Floor tracks bad-edge count at a rank correlation of +0.929, against only +0.676 for triangle count. A roof panel with 19 bad edges floors at 240 triangles where the whole garage, with 5,976, floors at 39,524 — 164× lower. Six of twelve parts weld to zero non-manifold edges and floor between 2 and 95 triangles. There is even a clean counterexample proving it is edges and not size: a door frame, a component, carries 5,026 bad edges and floors at 84,260 — worse than the entire building.
The other half lost, twelve meshes to zero. Quadric collapse beat planar dissolve at every matched triangle count on every mesh, by 3.7× to 20.3×, including on the flattest slab we measured. But the reason is a keeper, and it is sharper than the hypothesis it replaced: flatness buys planar REACH, never planar ACCURACY. How far dissolve gets correlates with flatness at +0.930. How much error it costs per triangle correlates at +0.350 — and that penalty widens to +0.580 as parts get flatter. Flat things can be crushed further and are crushed worse.
And then the floor stopped mattering

The kit of generated parts came in at 156,951 drawn triangles — a fourfold LOSS against the single generated building — and the parts do not tile: generated panels share no edge profile, so butt-jointed at exact pitch every joint on the front wall gapped, 12.0 mm median.
The control arm won outright. The same garage as seventeen authored boxes wearing materials baked off the generated components is 204 triangles and 4 draw calls. Twelve of those buildings are still 4 draw calls. And the two things that actually decide shipping are both won there and neither is won by decimation: the doorway is 5.0 × 4.0 m because somebody wrote 5.0 × 4.0 down (proved by swept ray — a 3.0 × 3.5 m truck box passes 625 of 625 samples), and the collision hull is just the box planes, analytic and watertight, where a decimated generated mesh is not watertight enough to derive collision from at all.
Look at the bottom row of that picture, though, because it is the honest part. The generated garage is better looking and it is not close — the sag in the roofline, the irregular corrugation, the way light catches a wall that was never flat. The authored one is a box. What the box buys is everything else.
So the reusable thing is the material, not the mesh

That is the pipeline now: generate a component once, keep its SURFACE and throw the geometry away, and dress authored boxes with it forever. The generation cost is paid once per material and amortises over every building that ever wears it. Four sets are in the library — steel, concrete, brick, roof — each with colour, normal and height maps, a physical tile size in metres, and their tiling repaired from a seam ratio as bad as 63.5 down to about 1.03.
The gate we wrote for it found a real defect on its first pass: only one of the four height maps is usable. It needs two witnesses because the failures are unrelated. Relief over tile size catches brick and roof — the bake took its depth range from the whole generated block rather than its face, and since the generator inflates a flat panel into a 1.18 m slab, a 2 cm mortar recess ends up occupying under 2% of the byte range. That is the almost-white image above. How much of the byte range is actually used catches concrete, which passes the first test and is still empty, because a genuinely flat slab has nothing to capture. Every verdict is recorded per material and the gate asserts the record matches the pixels — a library is allowed to hold a known-bad map, it is not allowed to lie about which one.
Next on the bench: the location buildings and a run of abandoned ruins to explore, authored from this kit, with something worth finding inside them. Which turns out to need one more thing — the pickups this game already has sit on a 45-second timer, so anything dropped in a ruin evaporates before you could ever come back for it. The answer is containers: chests, lockers, desks, free-floating inventories anchored to the world instead of to a clock. That is being built now.
The machines that will be parking in these are already out there: the arena is live.